Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add filters








Language
Year range
1.
Chinese Journal of Tissue Engineering Research ; (53): 3621-3627, 2015.
Article in Chinese | WPRIM | ID: wpr-467253

ABSTRACT

BACKGROUND:Because of convenient source, multi-lineage differentiation and low immunogenicity, bone marrow mesenchymal stem cels are the ideal cel type to serve as vectors of transgenic cels in pain management. However, the replicative senescence and smal amount of cels obtained from the bone marrow restrict the application of bone marrow mesenchymal stem cels in pain research. OBJECTIVE:To construct human telomerase reverse transcriptase (hTERT)-immortalized rat bone marrow mesenchymal stem cels as transgenic celular vectors for pain therapy. METHODS:Bone marrow mesenchymal stem cels were obtained from whole rat bone marrow, and then transfected with a lentivirus containing the hTERT (pLV-Puro-EF1α-hTERT) folowed by puromycin selection. hTERT expression and telomerase activity in these transfected cels were determined by RT-PCR and TRAP. Morphological changes, capacity of cel growth and multi-lineage differentiation, chromosome karyotype and tumorigenicity were observed in vitro. Moreover, the expression of cel surface molecule, Nestin, MHC-I and MHC-II in transfected cels were also detected by flow cytometry and immunocytochemistry. RESULTS AND CONCLUSION: The bone marrow mesenchymal stem cels geneticaly modified by hTERT could be cultured and passaged through 30 generations in vitro. Compared to the primary and negative transfected cels, the hTERT-modified bone marrow mesenchymal stem cels showed higher expression of hTERT mRNA, telomerase activity and cel proliferation. Most of transfected cels stayed at G2/M and S stages. The proliferation index of the transfected cels were increased dramaticaly. The positive rates of CD29, CD44 and CD90 were over 70%, but the positive rates of CD34 and CD45 were less than 5%. Transfected cels were positive for Nestin in the cytoplasm, but negative for MHC-1 and MHC-11. In addition, this cel line continued to exhibit the characteristics of fibroblastic bone marrow mesenchymal stem cels, including phenotype, differentiation into osteoblasts, adipocytes and neuron-like cels. No chromosome abnormality and tumor formation were observed in this experiment. Taken together, these data suggests that the rat bone marrow mesenchymal stem cels immortalized by hTERT gene are constructed successfuly and stil maintain major stem cels characteristics, which provide safe and stable cel vectors as research base for pain therapy.

2.
Chinese Journal of Medical Aesthetics and Cosmetology ; (6): 355-360, 2014.
Article in Chinese | WPRIM | ID: wpr-473012

ABSTRACT

Objective To evaluate the reliability of the panoramic radiographs for diagnosing mandibular asymmetry.Methods A total of 25 cases with no asymmetry in chief complaint or in appearance were selected for symmetry group.Pa and PAC from 16 cases of facial asymmetry were selected for asymmetric group.Marker points were fixed,a reference line and the reference plane drawn,and then relevant measurement items determined.The repeatability of the fixed position was observed.The difference of all measurement items between the left and right on Pa in symmetry group and asymmetric group were compared respectively and the asymmetric rate of corresponding measuredvalues on two sides between two groups were observed too.Correlation test was used to evaluate the measured-values on Pa and PAC in asymmetric group.Results Dispersion became smaller with the help of reference line and reference plane.And the dispersion was larger when Me was used as a marker other than MF.Most measured-values in symmetry group on Pa and all measured-values in asymmetric group on Pa showed statistically significant difference (P< 0.05).The mean difference of CP-GoP distance representing the vertical measured-value was 4.73 mm (P<0.01); and the mean difference of GoP-MF distance representing the horizontal measured-value was 5.77 mm (P<0.01).The horizontal measurements on PA and PAC showed closer correlation (r=0.78~0.85,P<0.01) while the vertical was poorer (r=0.64,P<0.01).Conclusions This study suggests that marking assisted with reference line and reference plane could get a more repeatable fixed-point on Pa.MF point could be used as a fixed-point for measuring mandibular asymmetry on Pa and the Pa measurement can be used to evaluate mandibular asymmetry.

3.
Journal of Chinese Physician ; (12): 1628-1631, 2010.
Article in Chinese | WPRIM | ID: wpr-385146

ABSTRACT

Objective To investigate the reliability of cast measurements by comparing Photoshop and conventional hand-held method. Methods Maxillary standard plaster models from 10 orthodontic cases with crowding were enrolled in this study. The space available and the space required of anterior region were measured by using Photoshop in the digital pictures or conventional method used by 5 observers respectively.The measurement results of the same sample among every observer were analyzed with ANOVA, and the difference between the 2 methods was calculated and paired t test was used to analyze the data. Results The repeatability of measurement results was not good when the space available was measured with conven-tional method by different observer( M1 ~ M5 ), and the measurement results of M1 were significantly different from that of M3 and M5 respectively( P < 0.05 ). The repeatability of measurement results was relatively good when the space available was measured by using Photoshop, and the measurement results of M5 were significantly different from other observers ( P < 0.05 ). The measurement results of space required measured by different observer were very close, and the reproducibility was excellent when they were measured by means of Photoshop or conventional methods. Conclusion There were no much difference between Photoshop and conventional method to measure the required space. Photoshop had significant advantage over conventional method when available sRace was measured.

4.
Chinese Journal of Tissue Engineering Research ; (53): 2929-2932, 2010.
Article in Chinese | WPRIM | ID: wpr-402574

ABSTRACT

BACKGROUND: Heat-activated nickel-titanium (HANT) wire is a new type of arch wire in orthodontic treatment, characterizing by well memory alloy ability and uneasily deformation. However, environmental temperature may affect its performance.OBJECTIVE: To compare the effects of HANT and common nickel-titanium wire in clinical application.METHODS: A total of 80 patients who have accepted and finished orthodontic treatment in the First Affiliated Hospital of Sun,Yat-sen University from July 2006 to November 2008 were randomly divided into two groups. The common group was treated with common arch wire in aligning and leveling stages, while the HANT group was treated using HANT in aligning and leveling stages. Tooth extracted cases were matched to non-tooth extracted cases. Indicators, such as time span for alignment, total treating time, times for wire breaking, times for bracket shedding, and times for return visits, were measured.RESULTS AND CONCLUSION: There was significant difference in treating time and times for wire breaking between the two groups (P < 0.05), but there was no significant difference in the times for bracket shedding. Anaphylactic response, toxic reaction,and other adverse reactions were not observed in the HANT group. Therefore, HANT wire can simplify orthodontic operation,shorten operation time beside the chair, save the total treating time, and reduce chances of shedding brackets and breaking wires.

5.
Journal of Chinese Physician ; (12): 1463-1465, 2008.
Article in Chinese | WPRIM | ID: wpr-396289

ABSTRACT

Objective To assess the reliability and validity of standardized facial photographs under natural head position (NHP) in assessment of mandibular asymmetry cases. Methods Standardized facial photographs (SFP) and posteroanterior cephalometry (PAC) were taken under natural head position from 25 mandibular asymmetry eases (14 boys and 11 girls), aged 14 to 29 years old. Distances from 8 landmarks to the vertical reference line were measured. The difference and the asymmetry ratio of two sides were calculated respectively. The relationship between the measurements of SFP and PAC were compared, and the repeatability of landmarks was assessed. Results Six measurements were significant different between two sides, 3 from SFP and 3 from PAC. Measurements from two ways were correlated a cer-tain extent. The repeatability of landmarks was satisfied. Conclusion Measurements from standardized facial photographs under NHP pres-ent a clinical useful method to quantify mandibular asymmetry.

6.
Journal of Chinese Physician ; (12)2001.
Article in Chinese | WPRIM | ID: wpr-525066

ABSTRACT

Objective To investigate the reliability and validity of three reference planes used in Wits appraisal measurement in evaluation of sagittal jaw relationship. Methods Lateral cephalo-radiography was performed before and after treatment in 25 patients with class Ⅱ division 1 of four premolars extraction. Wits appraisals were measured using the functional occlusal plane(FOP), bisected occlusal plane(BOP), and maxillary-mandibular bisector (MMB), respectively. The effect of different reference planes on Wits appraisals was analyzed. Results FOP and BOP showed a statistically significant change in their cant after treatment(P0.05). MMB Wits had the highest correlation with ANB angle (r=0.79, P

SELECTION OF CITATIONS
SEARCH DETAIL